Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
J. res. dent ; 10(2): 7-15, apr.-jun2022.
Article in English | LILACS, BBO | ID: biblio-1395875

ABSTRACT

Introduction: The objective of this systematic review was to answer the question: Does the intraradicular post transfixed in the dental crown increases the fracture resistance of weakened and directly restored teeth? Methods: Electronic databases (MEDLINE/PubMed, LILACS, SCOPUS, EMBASE, Scientific Electronic Library Online - SCIELO, and Central Register of Controlled Trials - CENTRAL) were searched until March 2021, without language or year restriction. Grey literature was also searched through Google scholar and OpenGrey repository. Only in vitro stud-ies were included that evaluated the influence of the use of intraradicular post trans-fixed in the crown in the buccopalatal/lingual direction in the fracture resistance of the dental crown. Relevant results were summarized and evaluated. The risk of bias was also assessed in the studies. Results: Initial screening of databases resulted in 249 studies, of which 109 were excluded for being duplicates. Of 140 eligible pa-pers, fourteen studies met the inclusion criteria and were selected for full-text read-ing. Of these, two studies were excluded for not having access to the full article. All selected articles were classified as low risk of bias. Conclusion: Based on the studies, it is possible to conclude that the use of a transfixed post in the crown increases the fracture resistance of weakened and directly restored teeth.


Subject(s)
Humans , Dentistry, Operative , Systematic Review , Tooth Crown , Dental Stress Analysis
2.
Braz. dent. j ; 32(5): 105-113, Sept.-Oct. 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1350289

ABSTRACT

Abstract The purpose was to evaluate, in vitro, the fracture strength of teeth restored with 0.3- or 0.6-mm-thick occlusal veneers made of Vita Enamic® bonded to enamel or dentin. Fifty third molars were allocated into five groups (n=10): Group C - control (sound teeth); Group 0.3E - 0.3-mm-thick occlusal veneers bonded to enamel; Group 0.6E - 0.6-mm-thick occlusal veneers bonded to enamel; Group 0.3D - 0.3-mm-thick occlusal veneers bonded to dentin; Group 0.6D - 0.6-mm-thick occlusal veneers bonded to dentin. After luting with Single Bond Universal and Filtek Z-100, the samples were subjected to fracture strength test in a universal testing machine. The fractures were classified as irreparable and reparable. Data were analyzed with 2-way and 1-way ANOVA (α=.05) followed by Tukey's test. The teeth restored with 0.3-mm-thick occlusal veneers (2658 N) achieved significantly higher fracture strength compared to the teeth restored with 0.6-mm-thick occlusal veneers (2070 N) (p=0.017). The teeth restored with occlusal veneers bonded to enamel (2648 N) had significantly higher fracture strength compared to the teeth restored with occlusal veneers bonded to dentin (2049 N) (p=0.015). Group C (3355 N) and Group 0.3E (2965 N) did not differ significantly from each other, being the fracture strength significantly higher than the other groups (p<0.05). The fractures were predominantly reparable. The teeth restored with 0.3-mm-thick occlusal veneers achieved higher fracture strength compared to the teeth restored with 0.6-mm-thick occlusal veneers. The supporting substrate influenced the fracture strength, which was higher for the teeth restored with occlusal veneers bonded to enamel.


Resumo O objetivo foi avaliar, in vitro, a resistência à fratura de dentes restaurados com facetas oclusais de Vita Enamic® com 0,3 ou o,6 mm de espessura e cimentadas em esmalte ou dentina. Cinquenta terceiros molares foram distribuídos em grupos (n=10): Grupo C-controle (dentes hígidos); Grupo 0,3E - facetas oclusais com 0,3 mm de espessura cimentados em esmalte; Grupo 0,6E - facetas com 0,6 mm de espessura cimentados em esmalte; Grupo 0,3D - facetas com 0,3 mm de espessura cimentados em dentina; Grupo 0,6D - facetas com 0,6 mm de espessura cimentados em dentina. Após cimentação com Single Bond Universal Filtek Z-100, as amostras foram submetidas ao teste de resistência à fratura em máquina de ensaio universal. As falhas foram classificadas em reparáveis e irreparáveis. Os resultados foram analisados pelo teste ANOVA de duas vias e uma via (α=0,05) seguido do teste de Tukey. Os dentes restaurados com facetas oclusais com 0,3 mm de espessura (2658 N) obtiveram resistência à fratura estatisticamente superior aos dentes restaurados com facetas com 0,6 mm (2070 N) (p=0.017). Os dentes restaurados com facetas cimentadas em esmalte (2648 N) tiveram resistência à fratura estatisticamente maior comparada aos dentes restaurados com facetas cimentadas em dentina (2049 N) (p=0.015). Grupo C (3355 N) e Grupo 0,3E (2965 N) não diferiram estatisticamente entre si, tendo resistência à fratura estatisticamente superior aos outros grupos (p<0.05). As fraturas foram predominantemente reparáveis. Os dentes restaurados com facetas oclusais com 0,3 mm de espessura apresentaram maior resistência à fratura comparada aos dentes restaurados com facetas com 0,6 mm. O substrato influenciou a resistência à fratura dos dentes restaurados com facetas oclusais, sendo maior quando cimentadas ao esmalte.

3.
Stomatos ; 18(34): 29-39, Jan.-Jun. 2012. ilus, tab
Article in English | LILACS, BBO | ID: lil-693973

ABSTRACT

The aim of this study was to evaluate the influence of Nd:YAG laser on microtensile bond strength (μTBS) of different adhesive materials to human dentin. Eighteen human third molars were divided into 6 groups. Group 1 – adhesive system, Adper Single Bond 2 (SB); Group 2 – adhesive system, Clearfil SE Bond (CSEB); Group 3 – self-adhesive resin luting cement, RelyX Unicem; Group 4 – irradiation with Nd:YAG laser and application of SB; Group 5 – irradiation with Nd:YAG laser and application of CSEB; Group 6 – irradiation with Nd:YAG laser and application of RelyX Unicem. A composite resin block was built on the dentin surfaces, and sticks with a cross-sectional area of ~0.80 mm2 were obtained. Twenty specimens per group were selected and subjected to μTBS testing in a universal testing machine. According to the analysis of variance and Tukey test (α = 0.05), the highest μTBS mean was obtained with CSEB (41.75 MPa) without laser irradiation, but this value was not statistically different from CSEB with laser irradiation (33.42 MPa). Mean μTBS of SB without (32.15 MPa) and with (35.38 MPa) laser irradiation did not differ statistically. The lowest μTBS values were obtained for RelyX Unicem, and the group without laser irradiation showed statistically higher values (14.50 MPa) than those found with laser irradiation (7.53 MPa). Nd:YAG laser did not significantly reduce bond strength of the adhesive systems under study, except for the self-adhesive resin luting cement.


O objetivo desse estudo foi avaliar a influência do laser Nd:YAG na resistência à microtração de diferentes materiais adesivos à dentina humana. Dezoito terceiros molares humanos foram divididos em 6 grupos. Grupo 1 – Adesivo Adper Single Bond 2 (SB), Grupo 2 – Adesivo Clearfil SE Bond (CSEB), Grupo 3 – Cimento resinoso autoadesivo RelyX Unicem, Grupo 4 – irradiação com laser de Nd:YAG e aplicação de SB, Grupo 5 – irradiação com laser de Nd:YAG e aplicação de CSEB e Grupo 6 – irradiação com laser de Nd:YAG e aplicação de RelyX Unicem. Um bloco de resina composta foi confeccionado sobre essas superfícies de dentina tratadas e os espécimes foram seccionados para obtenção de palitos de 0,80 mm2. Vinte espécimes foram selecionadas por grupo e submetidos a resistência adesiva à microtração (μTBS) em máquina de ensaio universal. De acordo com a análise de variância e teste de Tukey (α = 0,05), a maior média μTBS foi obtida com CSEB (41,75 MPa) sem irradiação por laser, esse valor não diferiu estatisticamente do CSEB com irradiação por laser (33,42 MPa ). A μTBS média de SB sem (32,15 MPa) e com (35,38 MPa) irradiação do laser não diferiram estatisticamente entre si. Os menores valores de μTBS foram obtidos para RelyX Unicem, sendo o valor sem irradiação por laser (14,50 MPa) estatisticamente superior ao com (7,53 MPa). O Laser de Nd: YAG não diminuiu significativamente a resistência de união dos sistemas adesivos estudados, apenas para o cimento resinoso autoadesivo.


Subject(s)
Dental Cements , Lasers/adverse effects , Lasers , Composite Resins , Materials Science , Analysis of Variance , Dentin , Dental Materials , Materials Testing
5.
Rev. odonto ciênc ; 23(4): 325-329, out.-dez. 2008. ilus, tab, graf
Article in English | LILACS, BBO | ID: lil-500144

ABSTRACT

Purpose: This study evaluated the influence of different methods of dentin surface pre-treatment on microtensile bond strength and failure mode of a single-bottle adhesive. Methods: Twenty-four third molars were embedded in acrylic resin and ground until exposure of occlusal dentin. Six groups were tested according to the dentin surface pre-treatment: G1) 35% phosphoric acid (pa) (positive control); G2) slurry of pumice + pa; G3) air-abrasion with 25μm-aluminum oxide + pa; G3) air abrasion with 50μm-aluminum oxide + pa; G5) air abrasion with sodium carbonate + pa; G6) no treatment (negative control). The adhesive Single Bond (3M-ESPE) was applied on the dentin surface and photoactivated before a 6mm-height composite restoration was built (Z250, 3M-ESPE). After storage in distilled water at 37ºC for 24h, all specimens (sectional area of 1mm²) were subjected to a microtensile bond strength test at a crosshead speed of 0.5mm/min. Results: Bond strength mean values (MPa) were: G1=29.28, G2=21.04, G3=21.66, G4=18.94, G5=19.90, and G6=19.03. Only G1 was statistically different from the other groups (ANOVA and Tukey's test, α=0.05). SEM images of the adhesive interface after rupture showed prevalence of mixed failure type (adhesive fracture between dentin and adhesive agent plus partial cohesive fracture in the composite restoration or dentin) for all groups but G6. Conclusion: The use of cleaning agents on dentin surface might not be necessary for adhesive procedures with dentin total acid-etching.


Objetivo: Este estudo avaliou a influência de diferentes métodos de pré-tratamento da superfície dentinária sobre a resistência de união à microtração e modo de falha de um sistema adesivo de frasco único. Metodologia: Vinte e quarto terceiros molares foram incluídos em resina acrílica e desgastados até exposição da dentina oclusal. Seis grupos foram testados de acordo com o pré-tratamento da dentina: G1) ácido fosfórico a 35% (pa) (controle positivo); G2) pasta de pedra- pomes + pa; G3) jateamento com óxido de alumínio 25μm + pa; G3) jateamento com óxido de alumínio 50μm + pa; G5) jateamento com carbonato de sódio + pa; G6) sem tratamento (controle negativo). O sistema adesivo Single Bond (3M-ESPE) foi aplicado na superfície dentinária e fotoativado antes da simulação de uma restauração de resina de 6mm de altura (Z250, 3M-ESPE). Após armazenamento em água destilada a 37ºC por 24h, todos os espécimes (área transversal de 1mm²) foram submetidos ao teste de microtração à velocidade de 0,5mm/min. Resultados: Os valores médios de resistência de união (MPa) foram: G1=29,28; G2=21,04; G3=21,66; G4=18,94; G5=19,90; e G6=19,03. Somente o G1 foi estatisticamente diferente dos demais grupos (ANOVA e teste de Tukey, α=0,05). A observação em MEV da interface adesiva após ruptura mostrou prevalência de falha do tipo mista (fratura adesiva entre dentina e agente adesivo associada à fratura coesiva parcial na restauração de resina ou dentina) para todos os grupos, exceto G6. Conclusão: O uso de agentes de limpeza na superfície dentinária pode não ser necessário para procedimentos adesivos com condicionamento ácido total da dentina.


Subject(s)
Humans , Dentin-Bonding Agents/pharmacology , Dentin , Tensile Strength
6.
Braz. oral res ; 20(2): 137-142, Apr.-June 2006. ilus
Article in English | LILACS | ID: lil-432190

ABSTRACT

O objetivo do presente estudo foi avaliar o estresse de contração de três resinas compostas sob diferentes métodos de fotoativação: fotoativação convencional halógena (G1), fotoativação "soft-start" halógena (G2) e fotoativação por LED (G3). As resinas compostas testadas foram a Filtek Z-100 (3M/ESPE), Filtek Z-250 (3M/ESPE) e Solitaire 2 (Heraeus Kulzer). Para G1, um aparelho fotoativador XL-3000 (3M/ESPE) com intensidade de 507 mW/cm2 foi empregado. Em G2, o mesmo aparelho foi utilizado, mas com a intensidade reduzida nos primeiros 20 s (166 mW/cm2); em G3 foi utilizado um fotoativador LED Ultrablue I (DMC) com intensidade de 125 mW/cm2. O teste foi realizado com uma máquina de ensaio universal DL 2000 (EMIC) e duas matrizes metálicas com um espaço de 1 mm entre elas. A resina composta foi inserida no espaço entre as matrizes e fotopolimerizada de acordo com o protocolo supracitado. O estresse foi registrado nos diferentes períodos de tempo: 10, 20, 40, 60, 90 e 120 s. Um aumento linear significante do estresse de contração em relação ao tempo foi observado, exceto para a Z-100 em G2. No geral, a fotoativação por LED (G3) reduziu o estresse gerado em comparação com a fotoativação convencional halógena (G1). Em G3, a resina com co-iniciador na sua composição apresentou menor estresse em comparação com as outras resinas testadas. A combinação entre resina composta e o método de fotoativação produziu diferentes padrões de comportamento do estresse. A polimerização com LED reduziu o estresse de contração inicial nos três materiais e foi influenciada pela presença de co-iniciadores nas resinas compostas.


Subject(s)
Composite Resins/chemistry , Dental Stress Analysis/methods , Materials Testing , Analysis of Variance , Composite Resins/standards , Elasticity , Light , Time Factors
7.
Ciênc. odontol. bras ; 8(2): 45-53, abr.-jun. 2005. tab
Article in Portuguese | LILACS, BBO | ID: lil-428139

ABSTRACT

Objetivos: Os objetivos deste trabalho foram avaliar a resistência de união de adesivos simplificados a um cimento resinoso quimicamente ativado, assim como o efeito de um catalisador universal sobre estes valores, e a associação entre o pH dos adesivos e a resistência de união com o cimento resinoso. Materiais e Métodos: Foi confeccionado um bloco do cimento C&B Cement (Bisco), sendo o adesivo aplicado sobre este, seguido da construção de um segundo bloco. Todos os adesivos simplificados foram utilizados com e sem o catalisador BondLink (Den-Mat). Estes foram embutidosem resina acrílica, mantidos em recipientes à prova de luz por 24 horas, sendo então seccionados para obtenção de palitos com aproximadamente 0,49mm2. Ao total foram obtidos 25 corpos-de-prova para cada grupo. O pH de cada adesivo foi medido com fitas medidoras. A resistência de união foi verificada por meio do teste de flexão de três pontos que foi realizado em máquina de ensaio universal EMIC DL-2000. Resultados: Os valores médios de resistência de união (MPa) para cada adesivo, sem e com a aplicação do BondLink, foram os seguintes, respectivamente: Scotchbond Multi Uso (111,17); Single Bond (103,49 e 74,66); One Step Plus (105,94 e 72,88); Clearfil SE Bond (106,27 e 39,82); AdheSE (101,27 e 59,38); Adper Prompt L-Pop (17,16 e 46,47). Conclusões: Houve incompatibilidade somente entre o adesivo Adper Prompt L-Pop e o cimento. O catalisador BondLink foi eficiente apenas para este adesivo. A união adesivo/cimento foi influenciada pelo pH dos adesivos


Subject(s)
Composite Resins , Dental Cements , Dental Materials , Dentin-Bonding Agents , Resin Cements
8.
Säo Paulo; s.n; 2002. 160 p. ilus, tab, graf. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-312824

ABSTRACT

O objetivo deste experimento foi avaliar, in vitro, a resistência à traçäo do adesivo Single Bond (3M) aplicado sobre a superfície interna das resinas compostas para restauraçöes indiretas belleGlass (JenericPentron), Sculpture (SybronKerr) e Targis (Ivoclar) tratadas com laser de Er: YAG, ácido fluorídrico 10 por cento ou jateamento com óxido de alumínio. Setenta amostras de cada uma das resinas compostas para restauraçöes indiretas estudadas foram divididas em sete grupos de dez elementos cada: 1) controle (sem tratamento ); 2) laser de Er: YAG (200 mJ, 10 Hz, 25 J/cm², por 5 segundos a sem refrigeraçäo por spray de ar-água); 3) ácido fluorídrico 10 por cento (3 minutos); 4) jateamento com óxido de alumínio 50 µm por 10 segundos; 5) laser de Er: YAG + ácido fluorídrico; 6) óxido de alumínio + ácido fluorídrico; 7) silano (RelyX - 3M). Os valores médios obtidos mostraram que os grupos irradiados com o laser de Er: YAG apresentaram os maiores valores de resistência adesiva com diferen;a estatisticamente significante em relaçäo aos outros grupos tratados com óxido de alumínio ou ácido fluorídrico. O padräo predominante de falhas na interface adesivo/resina composta mostrou os seguintes resultados: belleGlass - 87 por cento mistas; Sculpture - 70 por cento mistas e o Targis - 50 por cento de falhas coesivas no corpo da resina. Na análise de compostos orgânicos através da espectrometria por infravermelho foram identificados radicais hidroxila (OH-) com comprimento de onda na faixa de 2,86 µm a 3,33 µm nas três resinas compostas indicando que a sua presen;a pode estar relacionada à eficiência do laser no processo de ablaçäo. A inspeçäo das superfícies com auxílio da MEV demonstrou que o laser de Er: YAG promoveu a ablaçäo das resinas compostas, o jateamento com óxido de alumínio formou uma superfície irregular semelhante à lascas e o ácido fluorídrico ocasionou porosidades. Assim sendo, foi possível concluir que a utilizaçäo de tratamentos de superfície tais como laser de Er: YAG com parâmetros de 200 mJ e freqüência de 10 Hz, ácido fluorídrico 10 por cento ou jateamento com óxido de alumínio podem alterar a morfologia de superfície das resinas compostas belleGlass, Sculpture e Targis de modo que o efeito promovido pode influir de modo significativo nos valores de resistência à traçäo do adesivo Single Bond...


Subject(s)
Composite Resins , Dentin-Bonding Agents , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL